Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods

Electricity. Magnetism. General aspects
Including electromagnetism

GSO IEC 60865-1:2015 Files

GSO IEC 60865-1:2015 Scope

This part of IEC 60865 is applicable to the mechanical and thermal effects of short-circuit currents. It contains procedures for the calculation of – the electromagnetic effect on rigid conductors and flexible conductors, – the thermal effect on bare conductors. For cables and insulated conductors, reference is made, for example, to IEC 60949 and IEC 60986. For the electromagnetic and thermal effects in d.c. auxiliary installations of power plants and substations reference is made to IEC 61660-2. Only a.c. systems are dealt with in this standard. The following points should, in particular, be noted: a) The calculation of short-circuit currents should be based on IEC 60909. For the determination of the greatest possible short-circuit current, additional information from other IEC standards may be referred to, e.g. details about the underlying circuitry of the calculation or details about current-limiting devices, if this leads to a reduction of the mechanical stress. b) Short-circuit duration used in this standard depends on the protection concept and should be considered in that sense. c) These standardized procedures are adjusted to practical requirements and contain simplifications which are conservative. Testing or more detailed methods of calculation or both may be used. d) In Clause 5 of this standard, for arrangements with rigid conductors, only the stresses caused by short-circuit currents are calculated. Furthermore, other stresses can exist, e.g. caused by dead-load, wind, ice, operating forces or earthquakes. The combination of these loads with the short-circuit loading should be part of an agreement and/or be given by standards, e.g. erection-codes. The tensile forces in arrangements with flexible conductors include the effects of deadload. With respect to the combination of other loads the considerations given above are valid. e) The calculated loads are design loads and should be used as exceptional loads without any additional partial safety factor according to installation codes of, for example, IEC 61936-1 [1]1.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 2693:2022
 
Gulf Standard
The GCC Terrestrial Radio Receiver Specifications for AM/FM/T-DAB+

Recently Published from Electrical Sector

GSO IEC 63296-1:2024
IEC 63296-1:2021 
Gulf Standard
Portable multimedia equipment - Determination of battery duration - Part 1: Powered loudspeaker equipment
GSO IEC 60335-2-23:2024
IEC 60335-2-23:2016 
Gulf Standard
Household and similar electrical appliances - Safety - Part 2-23: Particular requirements for appliances for skin or hair care
GSO IEC 61558-2-4:2024
IEC 61558-2-4:2021 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers for general applications
GSO IEC 63174:2024
IEC 63174:2021 
Gulf Standard
Electrically operated toothbrushes - Methods for measuring the performance